253
-
IMPORTANT:
Executing the "apply" command reboots the EM card.
If two EM cards are installed, both cards are rebooted. While rebooting,
a bridge feature and SNMP feature are stopped. Accordingly, the
connection via management LAN of CPU blades and switch module is
temporarily disconnected. In addition, system monitoring by NEC
ESMPRO Manager is temporarily disabled. If a timeout error occurs,
connect them again after the active EM has rebooted.
NOTE:
When two EM cards are installed, check if the standby EM
works normally. If the standby EM is being activated or faulty, the
"apply" command cannot be executed.
Wait for a while until the standby EM becomes ready.
If the standby EM is faulty, remove it before executing the "apply"
command.
When you click the [Reset] button, the current settings are displayed.