Power Management
Use this page to specify the power redundancy mode, power control policy, power supply unit
waiting time at start, and upper limit specified for input voltage of Blade Enclosure in power
management provided by the EM card.
Power Redundancy Mode
Specify the power redundancy mode that the EM card uses.
–
N+N redundant mode:
Each power supply unit (PSU) is divided into two groups to configure the redundant
power supply system. AC line group 1 is composed of PSU1 and PSU2, and AC line
group 2 is composed of PSU3 and PSU4.
–
N+1 redundant mode:
Each power supply unit is controlled individually. To use one power supply unit in
addition to the required number of power supply units enables redundant power supply
system.
–
Non-redundant mode:
Power supply units are turned on (DC output) for several minutes as is necessary for
normal system operation.
NOTE:
The default setting is "N+N redundant mode".