281
-
Execute
Clicking the [Execute] button starts transfer of the update data file between EM cards. Upon
completion of transfer, the firmware of the target EM card is updated.
IMPORTANT:
After updating, the target EM card is rebooted
automatically. If the updating is executed on the active EM card, the
active EM card is switched to another EM card by switchover feature.
NOTES:
The combination of firmware revision available for synchronization
is as follows:
EM card that performs synchronization: Rev 06.00 or later
Another EM card: Rev 02.00 or later
To use this feature, you must be able to connect with both of Web
consoles of Active EM card and Standby EM card.
If you are going to perform revision synchronization on EM card of
which revision is Rev 10.08 or earlier while the other EM card of
which revision is Rev 11.xx or later, the EM cards are not
synchronized to Rev 11.xx or later. In this case, perform
synchronization on Web console of Rev11.xx side.
You cannot undo this operation, therefore, take extreme care to
execute it.
The screen as shown below appears on the EM card to be updated.
NOTE:
The on-screen information is not updated automatically. To
view the latest information, click the [Reload] button.
When update process is completed and the EM card is rebooted, this
screen is no further displayed even though the [Reload] button is
clicked.
Summary of Contents for N8405-019
Page 4: ... ii ...
Page 6: ... iv ...
Page 8: ... vi ...
Page 10: ... viii ...
Page 12: ... x ...
Page 20: ......
Page 231: ... 211 N8403 099 F N8403 100 F ...
Page 237: ... 217 Figure 3 Example of conflict of vIO information occurred when initializing the EM card ...