Field
Option
Description
Sun &
reflections
To increase the instrument measuring ability
during incident solar radiation and reflec-
tions, for example safety vests. This mode
has a considerable influence on the range
(restriction 100 - 150 m). This mode is auto-
matically deactivated when the instrument is
turned off.
Use ultra
fine aiming
Check box
Reduces the field of view of the ATRplus. The
setting is only applied for
Aim at target
:
Automatic
.
Automati-
cally meas-
ure points
Check box
Check this box to survey the target points
automatically. The instrument turns automat-
ically and measures the target point. For
instruments with automatic aiming.
Next step
Page
changes to the
Report sheet
page.Refer to "36 Apps - General".
49.2.3
Creating New Point Groups
The points to be used for Sets of Angles can be selected and the first set
measured. The measurement settings of the first measurement to each point
are used for all further sets.
Highlight
Create a new group
in
Measure sets of angles
and
OK
.
Key
Description
Store
To store the new points group.
Fn
Settings
To configure the Sets of Angles app.
Description of fields
Field
Option
Description
Point group
name
Editable field
The name of the points group.
Description
Access
New Point Group
854