Description
Especially when checking points it is useful to enable the
Quality control
cri-
teria available. For every point stored, the chosen parameters are checked.
When
Quality control
criteria is fulfilled, the difference icons are turning
green, and the measured point can be directly stored. If the check limits are
exceeded a warning is shown. This function guarantees a higher productivity as
it is no longer necessary to check the values for every shot taken.
Description of fields
Field
Option
Description
Check dif-
ferences
before stor-
ing
Check box
When this box is checked, a position check is
done when storing a staked point. When the
defined tolerance is exceeded, the stakeout
can be repeated, skipped or stored.
When this box is not checked, no quality
check is done during stakeout of points.
Differences
to check
☞
Depending on this selection the
following lines are enabled/disa-
bled.
Chainage,
offset &
height
Check for chainage, horizontal offset and
height.
Chainage &
offset
Check for chainage and horizontal offset.
Position &
height
Check for 2D position and height.
Position
Check for 2D position.
Height
Check for height.
Chainage
limit
From
0.001
to
100
Maximum difference in chainage.
Offset limit
From
0.001
to
100
Maximum horizontal offset from defined
position.
Position
limit
From
0.001
to
100
Maximum radial horizontal distance.
Height limit
From
0.001
to
100
Maximum height difference.
Next step
Page
changes to the
Heights
page.
Settings,
Quality control page
570