Field
Option
Description
Dataset
When the working job has at least one avail-
able linked job, the data for the setup can be
selected from the data set.
The option is available when all linked jobs
are set to hidden or if all points in the data
set are filtered out.
The option is unavailable when the jobs in
the data set are unavailable on the data stor-
age devcies.
Enter new
point
Pressing
OK
opens a panel where a new
point can be typed in. After pressing
Store
there, the Setup app continues.
GS - Smart-
Station
Available when TS and GS are used. Press
OK
to open the GSMeasure app. After measuring
a point with
Measure
,
Stop
,
Store
there,
the Setup app continues. Refer to "54.1.2
☞
In order to use GS, a coordinate
system for the setup is required
and must be attached to the job. If
not, then a coordinate system
must be selected, or local coordi-
nates for the setup must be typed
in, during the setup process.
☞
To obtain the correct elevation of
the setup point, measure the
instrument height as usual and
ensure that the antenna type is
set to the relevant SmartStation
antenna.
☞
If SmartPole is used in the setup or
later in Measure, remember to
update the antenna type after fin-
ishing the SmartStation measure-
ment.
Last used
setup
The setup used last in the Setup app is dis-
played.
Job
Selectable list The job from which the setup is selected.
Refer to "6.3 Choosing a Job".
Point ID
Display only
The point ID of the setup point.
Instrument
height
Editable field
The height of the instrument.
Easting
,
Northing
and
Height
Display only
The coordinates of the setup point.
Setup - TS
877