Field
Option
Description
Page to
show
Selectable list Available when
Show additional page from
User defined pages
is checked.
The names of the available pages.
Next step
Page
changes to the
Quality control
page.
Description of fields
Field
Option
Description
Check for
errors
before stor-
ing
Check box
The entered horizontal, vertical and distance
tolerances are checked during the measure-
ments to verify accurate pointing and meas-
urements.
Hz tolerance
Editable field
Tolerance for horizontal directions.
V tolerance
Editable field
Tolerance for vertical directions.
Distance
tolerance
Editable field
Tolerance for distance.
Check for
backsight
height
Check box
The entered height tolerance for the back-
sight point is checked during the measure-
ments to verify accurate pointing and meas-
urements.
Height limit
Editable field
Tolerance for the backsight height.
Next step
Page
changes to the
Report sheet
page. Refer to "36 Apps - General".
58.7
Traverse Methods
58.7.1
Starting Traverse
The quickest setup method is described.
1.
Start the Traverse app.
2.
Traverse
Select
Create a new traverse
.
3.
OK
to access
New Traverse
.
4.
New Traverse
Type in the name of the new traverse.
5.
OK
to access
Settings
.
Check the settings.
6.
OK
to access
Total Station Setup
.
Any standard setup method can be used.
7.
Set
to set the setup and orientation.
8.
A confirmation window is displayed.
Forsght pt
Settings,
Quality control page
Start traverse step-
by-step
954
Traverse