Select
Leica Captivate - Base: Settings
\
GS base
\
GNSS raw data log-
ging
.
Key
Description
OK
To accept changes.
Description of fields
Field
Option
Description
Log GNSS
raw data
Check box
Activates raw data logging.
Log data
every
From
0.05
sec
to
300.0
sec
Rate at which raw observations are logged.
Recommendations:
•
For static operations with long baselines
and over long time
Rate: 15.0 sec
or
Rate: 30.0 sec
.
•
For base stations for post-processed and
real-time kinematic rovers,
Rate
at the
base should be the same rate as at the
rover.
Log data to
Selectable list Data can be logged in the Leica proprietary
MDB format or in RINEX.
GNSS Raw Data Log-
ging
248
Instrument - Base Settings