Field
Option
Description
Prompt
before turn
The method how the instrument turns is not
fixed but is selected when pressing
Position
.
Additionally to the three methods listed
above, an option allowing the instrument to
find the height on the peg is available:
a
b
c
Road_072
a Peg placed at the correct position
b First height, manually chosen direction
c Required height on the peg
For more information refer to "43.3.11 Work-
flow for Height (aim to stake ht) - for TS".
Position
limit
From
0.001
to
10
Maximum permitted radial horizontal dis-
tance.
Available for Tunnel and for Road/Rail with
Automatic behaviour
:
Position & meas-
ure
or
Automatic behaviour
:
Prompt
before turn
.
Height limit
From
0.001
to
10
Maximum height difference. Available for
Road and Rail.
Chainage
limit
From
0.001
to
10
Chainage tolerance of the position to stake
out.
Available for Tunnel and for Road/Rail with
Automatic behaviour
:
Position & meas-
ure
or
Automatic behaviour
:
Prompt
before turn
.
Offset limit
From
0.001
to
10
Maximum horizontal offset from defined
position. Available for Road and Rail.
Red laser
pointer
Defines when the visible red laser beam is
turned on during the automatic search of the
position.
Available for Tunnel and for Road/Rail with
Automatic behaviour
:
Position & meas-
ure
or
Automatic behaviour
:
Prompt
before turn
.
Always off
Visible red laser is turned off.
Turn on
when aimed
at pt
Visible red laser is turned on as soon as the
point is found.
Always on
Visible red laser is turned on during the
whole search.
☞
The laser can also be permanently
turned on by using the instrument
settings. Refer to "22.5 Lights &
accessories" for more information.