Key
Description
OK
To accept changes and continue to the next panel.
Page
To change to another page on this panel.
Description of fields
Field
Option
Description
Measure-
ment
sequence
B'F'...F''B''
All points are measured in face I, then meas-
ured in face II in reverse sequential order.
B'F'...B''F''
All points are measured in face I, then meas-
ured in face II.
B'B''F'F''...
Backsight point is measured in face I immedi-
ately followed by face II. Other points are
measured in face I, face II order.
B'B''F''F'...
Backsight point is measured in face I immedi-
ately followed by face II. Other points are
measured in alternating face order.
B'F'...
All points are measured in face I only.
When using
auto target
aiming,
automati-
cally meas-
ure targets
Check box
For instruments with automatic aiming and
this option checked, automatic aiming search
and automatic aiming measurements are
done to specified targets and subsequent
sets.
Next step
Page
changes to the
Quality control
page.
Description of fields
Field
Option
Description
Check for
errors
before stor-
ing
Check box
The entered horizontal, vertical and distance
tolerances are checked during the measure-
ments to verify accurate pointing and meas-
urements.
Hz tolerance
Editable field
Tolerance for horizontal directions.
V tolerance
Editable field
Tolerance for vertical directions.
Distance
tolerance
Editable field
Tolerance for distance.
Check the
backsight
height
Check box
The entered height tolerance for the back-
sight point is checked during the measure-
ments to verify accurate pointing and meas-
urements.
Height limit
Editable field
Tolerance for the backsight height.
Measure Foresight,
Automation behav-
iour page
Measure Foresight,
Quality control page
454