The parameters shown on this panel depend on the setting for
Stop measure-
ment based on
.
Key
Description
OK
To accept changes.
Description of fields
Field
Option
Description
Time at
point
Editable
fields
Sets the required observation time for each
point. Counting time starts when
Measure
is
pressed. The instrument stops measuring
when the set length of time is reached.
Number of
obs
Editable
fields
Sets the required number of observations
that are to be recorded at each point. Count-
ing observations starts when
Measure
is
pressed. The instrument stops measuring
when the set number of observations is
reached.
At logging
rate
Display only
Displays the rate at which static raw observa-
tions are logged as configured.
8+ satellites
for
,
7 satel-
lites for
,
6
satellites
for
,
5 satel-
lites for
and
4 satellites
for
Editable field
Sets the required observation time depend-
ing on the number of satellites available.
Counting time starts when
Measure
is
pressed. The instrument stops measuring
when the set length of time for a certain
number of satellites is reached.
Should the number of available satellites
change during observation, the observations
already recorded are taken into account.
Baseline
length
Selectable list Used for the calculation of the occupation
time for
Stop measurement based
on: Stop & go indicator
.
Extend
occupation
time by fac-
tor of
From
1.0
to
5.0
The factor extends the point occupation time
recommended by the software. It directly
influences the occupation time shown in
Time at point
in
Measure
.
Next step
1.
OK
closes the panel.
Parameters for Auto
Stop
Settings - Point storage
303