Description of fields
Field
Option
Description
Time limit
for predict-
ing target
location
From
1 s
to
5 s
If the target is lost when
Aim at target:
With lock
the path of the prism is predicted
for the selected number of seconds.
If no target
found after
prediction
then
Wait & lock
Perform no search after prediction.
Start fine
search
Perform search after prediction with ATRplus
in a dynamic
Fine search window
.
Start Cube-
Search
Perform search after prediction with Power-
Search. Activate PowerSearch on the
Power-
Search window
page.
Turn to last
measured
point
If the target is lost when
Aim at target:
With lock
, then the instrument turns back
to the last stored point. The field of view is
disabled while the instrument is reposition-
ing.
Next step
Page
changes to the
PowerSearch window
page.
Key
Description
OK
To accept changes and return to
Leica Captivate - Home
.
Set
To define new PowerSearch window.
Centre
To centre the PowerSearch window to the current position of
the telescope.
Show
To position the telescope to corners of PowerSearch window.
Page
To change to another page on this panel.
Description of fields
Field
Option
Description
Use Power-
Search win-
dow
Check box
If checked, PowerSearch searches in the
defined window.
Target Search,
PowerSearch window
page
Settings - TS instrument
255