Field
Option
Description
Positions
Editable field
Raw data is logged for a minimum number of
positions even when the
Position quality
better than
and
Height quality better
than
is already less than the specified maxi-
mum.
Position
update
Display only
Displays the value for
GS position update
rate
as configured in
Screen, Audio & Text
Input
,
Screen
page.
Number of
positions
Editable field
Sets the number the positions which must
be observed before the instrument stops
measuring. Counting the number of posi-
tions starts when
Measure
is pressed.
Baseline
length
Selectable list Used for the calculation of the occupation
time for
Stop measurement based
on: Stop & go indicator
.
Next step
OK
closes the panel.
25.4
TS offsets & checks
Offsets
The offset values are applied to measured points. The Offset function allows
offset points to be determined, for instance when the reflector cannot be set
up directly on a point. Transverse, longitudinal and/or elevation offsets can be
defined from the reflector position to the offset point. All the displayed and
recorded measurement data is in relation to the offset point.
Repeat measurement checks
The instrument can be configured to monitor sequentially stored measure-
ments and to notify the user if the coordinates lie within a defined range of
each other.
If configured, the X,Y coordinates of a point being stored can be compared to
the coordinates of the last previously stored point. If the difference is less than
the defined position tolerance then a warning is shown. It can now be decided
whether to store the point or not.
If configured, backsight target points and resection target points which were
measured during the setup procedure are then also checked in this manner.
Description
Settings - Point storage
305