Key
Description
OK
To accept changes and return to the panel from where this
panel was accessed.
Messages
To configure what NMEA messages are output, the rates and
the output timing method. Refer to paragraph "NMEA Mes-
Device
To create, select, edit or delete a device.
Description of fields
Field
Option
Description
Stream
NMEA mes-
sages from
the GS sen-
sor
Check box
Activates the output of NMEA.
Connect
using
GS Port 1
For GS10/GS25: The physical port P1 on the
box.
For GS14/GS15/GS16/GS18: The red LEMO
port.
GS Port 2
For GS10/GS25: The physical port P2 on the
box.
For GS15: The black LEMO port.
GS Port 3
For GS10: The physical port P3 on the box.
For GS15/GS25: The slot for a device.
GS Port 4
For GS25: The physical port P4 on the box.
GS BT
The Bluetooth port on the GS.
GS Internet
1
,
GS Internet
2
,
GS Internet
3
The Internet ports on the GS. If these ports
are not assigned to a specific connection,
then these ports are extra remote ports.
GS radio
Available for GS14/GS16.
GS modem
Available for GS14/GS16/GS18.
Device
Display only
Usually,
RS232
is used to transfer NMEA
messages.
NMEA Ver-
sion
4.0 (exten-
ded)
Backwards compatible to NMEA in Leica Cap-
tivate version 5.0 plus BeiDou support.
NMEA Output 1
200
Connections - All other connections