Key
Description
OK
To accept changes and return to the panel from where this
panel was accessed.
Content
To configure what is viewed in the page in the Measure
app. Available for
Automatically measure points
checked.
Page
To change to another page on this panel.
Description of fields
Field
Option
Description
Automati-
cally meas-
ure points
Check box
Activates the logging of auto points.
☞
All other fields on the panel are
active and can be edited.
Measure
new point
after cer-
tain
Time
Auto points are logged according to a time
interval. The time interval is independent
from the update interval for the position on
the panel.
Distance
The difference in distance from the last
stored auto point, which must be reached
before the next auto point is logged. The
auto point is logged with the next available
computed position.
Difference
in height
The height difference from the last stored
auto point, which must be reached before
the next auto point is logged. The auto point
is logged with the next available computed
position.
Distance or
height
Before the next auto point is logged, either
the difference in distance or the difference in
height must be reached. The auto point is
logged with the next available computed
position.
Distance &
time
An auto point is stored when the position of
the antenna/prism does not move more than
the distance configured in
Minimum dis-
tance between points
within the
Stop
time
.
Once a point has been stored, the position
must change more than the distance config-
ured in
Minimum distance between points
before the routine starts again.
Key press
An auto point is stored upon pressing
Meas-
ure
(for GS) /
Store
(for TS) in the
Measure
app, page. In the beginning, the chain to
which the auto points are assigned must be
started with
Start
. In the end, the chain
must be closed with
Stop
.
Measure - Auto Points
931