14.2
Connection Using Cable
The connection settings must be specified.
Key
Description
Back
To return to the previous panel.
Default
To return the fields back to their default values.
Next
To confirm the settings and to continue to the next panel.
Description of fields
Field
Option
Description
Baud rate
From
1200
to
115200
Frequency of data transfer from instrument
to device in bits per second.
Parity
None
,
Even
or
Odd
Error checksum at the end of a block of digi-
tal data.
Data bits
6
,
7
or
8
Number of bits in a block of digital data.
Stop bit
1
or
2
Number of bits at the end of a block of digi-
tal data.
Flow control None
or
RTS/CTS
Activates hardware handshake.
When the instrument/device is ready for
data, it asserts the Ready To Send line indi-
cating it is ready to receive data. This line is
read by the sender at the Clear To Send
input, indicating it is clear to send the data.
Next step
Next
and follow the instructions on the panel.
14.3
Connection Using Bluetooth
The panel shown depends on whether a last used Bluetooth ID is available for
the chosen instrument model.
Description
TS Connection Wizard
- Step 2
Description
Connections - TS connection wizard
157