LINE LOCKOUT
– 300 –
A2298-10
LINE LOCKOUT
PROGRAMMING
DESCRIPTION
DATA
Provide the system with Howler Tone sent
to locked-out stations, if required.
(1)
(2)
153
0 : Not sent
1 : To send
Assign the line lockout indication on the
DSS Console.
(1)
(2)
274
0 : Available
1 : Not available
When the Howler Tone is provided
(CM08>153: 1), assign Howler Tone send-
ing to required stations.
•
(1)
(2)
Y=04
X-XXXXXXXX: Station No.
1 : To provide
Specify the timing for Lockout Alarm.
•
(1)
(2)
Y=0
22
01-08: 4 sec.-32 sec.
(4 sec. increments)
If no data is set, the default setting is 28-32
sec.
Specify the number of stations in Line
Lockout to give a MN Alarm.
(1)
(2)
01
01-99: Number of Stations in Line
Lockout
If no data is set, no Lockout Alarm Display
functions.
CM13
CM41
CM42
START
CM08
END
Summary of Contents for NEAX 2000
Page 1: ...ND 70916 E ISSUE 1 Feature Programming Manual JANUARY 2000 NEC Corporation ...
Page 157: ...CALL QUEUING 137 A2131 10 CALL QUEUING PROGRAMMING Refer to CALL WAITING DISPLAY page 142 ...
Page 273: ...FAULT MESSAGE 253 A2247 10 FAULT MESSAGE PROGRAMMING Refer to Maintenance Manual ...
Page 402: ...PEG COUNT 382 A2382 10 PEG COUNT PROGRAMMING Refer to the CMB0 B3 of the Command Manual ...
Page 443: ...SELF DIAGNOSIS 423 A2412 10 SELF DIAGNOSIS PROGRAMMING Refer to the Maintenance Manual ...
Page 726: ... A16 A2A10 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 754: ... C26 A2C14 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 772: ...Page viii ND 91285 001 E Revision 1 0 DECEMBER 1999 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 1192: ...ND 91285 001 E DECEMBER 1999 Page 410 Revision 1 0 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 1197: ......
Page 1198: ......
Page 1199: ...ND 91285 002 E ISSUE 1 Model 100MX HOSPITALITY FEATURES AND SPECIFICATIONS OCTOBER 1999 ...