TRUNK ANSWER FROM ANY STATION (TAS)
– 534 –
A2523-10
To provide the External TAS Indicator via DK card:
DESCRIPTION
DATA
Assign the card number of DK to required
LEN.
NOTE:
The DK card number must be
assigned to the first LEN (Level
0) and the third LEN (Level 2) of
each LT slot.
(1)
(2)
000-763: LEN
E800-E831: DK Card No.
For PIM0/1 : E800-E807
For PIM2/3 : E808-E815
For PIM4/5 : E816-E823
For PIM6/7 : E824-E831
Assign the TAS Group number assigned
by CM30 Y=17 to circuit number of DK
card.
NOTE:
MP built-in External Equipment
Interface is not available for Ex-
ternal TAS Indicator Connection.
(1)
(2)
XX Y
XX: 00-31: DK Card No. assigned by
CM10 (E800-E831)
Y : 0-3: Circuit No.
13XX
XX: 00-63: TAS Group No. 00-63
assigned by CM30 Y=17
Specify the indication pattern on External
TAS Indicator.
(1)
(2)
00
01: 30 IPM (1 sec. ON/OFF)
02: 60 IPM (0.5 sec. ON/OFF)
03: 120 IPM (0.25 sec. ON/OFF)
07: Steady on
NONE : 120 IPM (0.25 sec. ON/OFF)
CM44
CM59
START
END
CM10
Summary of Contents for NEAX 2000
Page 1: ...ND 70916 E ISSUE 1 Feature Programming Manual JANUARY 2000 NEC Corporation ...
Page 157: ...CALL QUEUING 137 A2131 10 CALL QUEUING PROGRAMMING Refer to CALL WAITING DISPLAY page 142 ...
Page 273: ...FAULT MESSAGE 253 A2247 10 FAULT MESSAGE PROGRAMMING Refer to Maintenance Manual ...
Page 402: ...PEG COUNT 382 A2382 10 PEG COUNT PROGRAMMING Refer to the CMB0 B3 of the Command Manual ...
Page 443: ...SELF DIAGNOSIS 423 A2412 10 SELF DIAGNOSIS PROGRAMMING Refer to the Maintenance Manual ...
Page 726: ... A16 A2A10 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 754: ... C26 A2C14 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 772: ...Page viii ND 91285 001 E Revision 1 0 DECEMBER 1999 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 1192: ...ND 91285 001 E DECEMBER 1999 Page 410 Revision 1 0 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 1197: ......
Page 1198: ......
Page 1199: ...ND 91285 002 E ISSUE 1 Model 100MX HOSPITALITY FEATURES AND SPECIFICATIONS OCTOBER 1999 ...