FAULT MESSAGE
GENERAL DESCRIPTION
This feature stores fault messages of the system and displays the fault messages on the MAINTE-
NANCE ADMINISTRATION TERMINAL (MAT). When a fault has occurred, this feature provides
alarm indication to external circuits by driving relay contacts.
STATION APPLICATION
Not applicable
OPERATING PROCEDURE
Refer to the Command Manual and MATWorX User’s Guide.
SERVICE CONDITIONS
1. Print-out of FAULT MESSAGEs is possible through the printer connected to the MAT. Print-out is by
manual request only.
2. The maximum number of FAULT MESSAGEs that can be stored in PBX is 64.
3. For providing external alarm indication, equipment such as a Fault Display Panel must be installed.
External alarm indication is provided using a contact to ground at the main distribution frame. One
contact is needed for minor alarms, and one contact is needed for major alarm.
4. The following FAULT MESSAGEs are provided:
•
System initialized
•
MP-FP/AP communication failure
•
FP/AP board down/turned back to normal condition
•
DTI line failure/turned back to normal condition
•
CCH link connection failure/turned back to normal condition
•
Number of lock-out station was more than/less than a fixed number
•
SMDR output buffer memory overflow/turned back to normal condition
•
DCH/BRT D-channel link connection failure/turned back to normal condition
•
Number of Line fault was more than/less than a fixed number
•
Alarm for predetermined time: Battery Change Alarm (three years)
5. This feature is also available form the Customer Administration Terminal (CAT).
Summary of Contents for NEAX 2000
Page 1: ...ND 70916 E ISSUE 1 Feature Programming Manual JANUARY 2000 NEC Corporation ...
Page 157: ...CALL QUEUING 137 A2131 10 CALL QUEUING PROGRAMMING Refer to CALL WAITING DISPLAY page 142 ...
Page 273: ...FAULT MESSAGE 253 A2247 10 FAULT MESSAGE PROGRAMMING Refer to Maintenance Manual ...
Page 402: ...PEG COUNT 382 A2382 10 PEG COUNT PROGRAMMING Refer to the CMB0 B3 of the Command Manual ...
Page 443: ...SELF DIAGNOSIS 423 A2412 10 SELF DIAGNOSIS PROGRAMMING Refer to the Maintenance Manual ...
Page 726: ... A16 A2A10 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 754: ... C26 A2C14 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 772: ...Page viii ND 91285 001 E Revision 1 0 DECEMBER 1999 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 1192: ...ND 91285 001 E DECEMBER 1999 Page 410 Revision 1 0 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 1197: ......
Page 1198: ......
Page 1199: ...ND 91285 002 E ISSUE 1 Model 100MX HOSPITALITY FEATURES AND SPECIFICATIONS OCTOBER 1999 ...