ANALOG PORT ADAPTER-D
term
– 20 –
A2018-10
HARDWARE REQUIRED
Analog Port Adapter
DESCRIPTION
DATA
Assign an virtual key for analog terminal.
•
(1)
(2)
Y=00
Analog Terminal Station No. +
+ Key
No.
X-XXXXXXXX: Analog Terminal Sta-
tion No. assigned by
CM10.
Assign an analog terminal station number
as Prime Line.
(1)
(2)
X-XXXXXXXX: Analog Terminal Sta-
tion No.
X-XXXXXXXX: Analog Terminal Sta-
tion No.
Provide the Analog Port Adapter to the re-
quired station.
•
(1)
(2)
Y=34
X-XXXXXXXX: Analog Terminal Sta-
tion No.
0: To connect
Specify whether a ringing signal is sent to
the analog terminal.
•
(1)
(2)
Y=35
X-XXXXXXXX: My Line No.
0 : Not sent
1 : To send
Specify the PAD control of the analog ter-
minal.
•
(1)
(2)
Y=09
X-XXXXXXXX: Analog Terminal Sta-
tion No.
0 : Without PAD
1 : With PAD 6dB
CM90
A
END
CM93
CM13
,
Summary of Contents for NEAX 2000
Page 1: ...ND 70916 E ISSUE 1 Feature Programming Manual JANUARY 2000 NEC Corporation ...
Page 157: ...CALL QUEUING 137 A2131 10 CALL QUEUING PROGRAMMING Refer to CALL WAITING DISPLAY page 142 ...
Page 273: ...FAULT MESSAGE 253 A2247 10 FAULT MESSAGE PROGRAMMING Refer to Maintenance Manual ...
Page 402: ...PEG COUNT 382 A2382 10 PEG COUNT PROGRAMMING Refer to the CMB0 B3 of the Command Manual ...
Page 443: ...SELF DIAGNOSIS 423 A2412 10 SELF DIAGNOSIS PROGRAMMING Refer to the Maintenance Manual ...
Page 726: ... A16 A2A10 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 754: ... C26 A2C14 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 772: ...Page viii ND 91285 001 E Revision 1 0 DECEMBER 1999 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 1192: ...ND 91285 001 E DECEMBER 1999 Page 410 Revision 1 0 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 1197: ......
Page 1198: ......
Page 1199: ...ND 91285 002 E ISSUE 1 Model 100MX HOSPITALITY FEATURES AND SPECIFICATIONS OCTOBER 1999 ...