ND-91285-001(E)
DECEMBER, 1999
Page 189
Revision 1.0
(1/1)
INCOMING CENTRAL OFFICE CALL TO TIE LINE CONNECTION
GENERAL DESCRIPTION
This service feature permits an Attendant to connect an incoming network exchange call, via a Tie
Line, to a station at a distant PBX.
STATION APPLICATION
DESK CONSOLE
SMART CONSOLE
OPERATING PROCEDURE
To connect an incoming call:
1. Attendant depresses
LDN
key and answers incoming trunk call.
2. Dial Tie Line access code; receive Dial Tone from distant PBX.
3. Dial distant PBX station number
4. Depress
RELEASE
key.
5. Tie Line and trunk call are connected.
SERVICE CONDITIONS
1. The Attendant can connect a trunk and Tie Line call either before or after the distant station goes off-
hook.
2. There is no limitation on the number of incoming trunks which may be connected to Tie Lines using
this feature.
3. Trunk to Trunk connection can be restricted Route to Route restriction assignments.
4. AUTOMATIC RECALL is work on incoming C.O. call to Tie Line connection before the distant sta-
tion answers.
5. This feature is applicable to the following types of Incoming C.O. calls:
•
DID
•
LDN
6. This feature allows an incoming C.O. trunk call to be extended via the Attendant to an outgoing Tie
Line trunk.
7. Loop-start C.O. trunks can be connected to Tie trunks since release supervision is provided by the Tie
trunks.
Summary of Contents for NEAX 2000
Page 1: ...ND 70916 E ISSUE 1 Feature Programming Manual JANUARY 2000 NEC Corporation ...
Page 157: ...CALL QUEUING 137 A2131 10 CALL QUEUING PROGRAMMING Refer to CALL WAITING DISPLAY page 142 ...
Page 273: ...FAULT MESSAGE 253 A2247 10 FAULT MESSAGE PROGRAMMING Refer to Maintenance Manual ...
Page 402: ...PEG COUNT 382 A2382 10 PEG COUNT PROGRAMMING Refer to the CMB0 B3 of the Command Manual ...
Page 443: ...SELF DIAGNOSIS 423 A2412 10 SELF DIAGNOSIS PROGRAMMING Refer to the Maintenance Manual ...
Page 726: ... A16 A2A10 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 754: ... C26 A2C14 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 772: ...Page viii ND 91285 001 E Revision 1 0 DECEMBER 1999 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 1192: ...ND 91285 001 E DECEMBER 1999 Page 410 Revision 1 0 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 1197: ......
Page 1198: ......
Page 1199: ...ND 91285 002 E ISSUE 1 Model 100MX HOSPITALITY FEATURES AND SPECIFICATIONS OCTOBER 1999 ...