ND-91285-001(E)
DECEMBER, 1999
Page 220
Revision 1.0
(2/3)
MESSAGE CENTER INTERFACE (MCI) (CONT’D)
OPERATING PROCEDURE (CONT’D)
To retrieve a voice mail message from the VMS:
1. The MW lamp is lit or the LCD displays “
MESSAGE
”
2. Go off hook and receive Dial Tone.
3. Dial the Voice Mail station number; receive Ringback Tone.
The LCD displays “
xxxx
” (where
xxxx
is Voice Mail station number)
4. Follow the instructions given by the VMS.
SERVICE CONDITIONS
1. The VMS is interfaced to the system through the LC card or PN-AUC card. (The PN-4LCD provides
disconnect supervision in the form of a momentary loop open. The PN-4LCF provides disconnect
supervision in the form of a momentary reverse. The PN-4LCF is applicable for Australia only.) The
UCD or STATION HUNTING feature is usually provided with the VMS station.
2. The Application Processor (AP00) is required to make a data link with a customer supplied VMS.
3. Messages can be retrieved from any D
term
, DTMF telephone, or the Attendant Console, but not from
DP telephones.
4. The MCI is available to a direct call or a forwarded call from a station/trunk/Attendant to the VMS.
For details of the connecting patterns, refer to the Instaration Procedure Manual/Feature Programming
Manual.
5. Stations can set CALL FORWARDING or SPLIT CALL FORWARDING - ALL CALLS, - NO
ANSWER, and - BUSY LINE to the VMS. The system sends out incoming call information to the
VMS. Calling a station which has CALL FORWARDING set to the VMS is automatically answered
by the VMS.
6. The MCI can control the LCD display of a D
term
for “Message” Indication. The number of messages
is not displayed.
7. When the MW lamp control is activated with the MCI, the lamp control from the following equipment
will not be provided:
•
From the PROPERTY MANAGEMENT SYSTEM (PMS)
•
From the station (by dialing the access code)
•
From the DIRECT STATION SELECTION (DSS) CONSOLE
•
From the HOTEL/MOTEL FRONT DESK TERMINAL
•
From the Attendant Console
8. In case of the MW lamp control through CCIS network, only one system should be programmed to
control that, in system programming.
9. It is ensured that the system controls MW lamp normally when the time interval between messages to
be sent out from the VMS to the MCI is a minimum of 350 msec. or more.
Summary of Contents for NEAX 2000
Page 1: ...ND 70916 E ISSUE 1 Feature Programming Manual JANUARY 2000 NEC Corporation ...
Page 157: ...CALL QUEUING 137 A2131 10 CALL QUEUING PROGRAMMING Refer to CALL WAITING DISPLAY page 142 ...
Page 273: ...FAULT MESSAGE 253 A2247 10 FAULT MESSAGE PROGRAMMING Refer to Maintenance Manual ...
Page 402: ...PEG COUNT 382 A2382 10 PEG COUNT PROGRAMMING Refer to the CMB0 B3 of the Command Manual ...
Page 443: ...SELF DIAGNOSIS 423 A2412 10 SELF DIAGNOSIS PROGRAMMING Refer to the Maintenance Manual ...
Page 726: ... A16 A2A10 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 754: ... C26 A2C14 10 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 772: ...Page viii ND 91285 001 E Revision 1 0 DECEMBER 1999 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 1192: ...ND 91285 001 E DECEMBER 1999 Page 410 Revision 1 0 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 1197: ......
Page 1198: ......
Page 1199: ...ND 91285 002 E ISSUE 1 Model 100MX HOSPITALITY FEATURES AND SPECIFICATIONS OCTOBER 1999 ...