background image

1

OPTION CARDS

NETSILON 9 / 11

Installation guide

On receipt, ensure that the product has not been damaged during transportation and report any concerns to the carrier.

BODET TIme & Sport

1 rue du Général de Gaulle
49340 Trementines, France
Tel. support Export: 02.41.71.72.33

Ref.: 608551 C

www.bodet-time.com

T

IME SERVER

OPTION CARDS

Summary of Contents for NETSILON 11

Page 1: ...sure that the product has not been damaged during transportation and report any concerns to the carrier BODET TIme Sport 1 rue du Général de Gaulle 49340 Trementines France Tel support Export 02 41 71 72 33 Ref 608551 C www bodet time com TIME SERVER OPTION CARDS ...

Page 2: ...2 INTRODUCTION 5 2 1 Checking the package 5 2 2 Saving the configuration 5 2 3 Safety 5 3 MECHANICAL INSTALLATION 6 4 ELECTRICAL CONNECTIONS 9 4 1 Option cards 9 5 QUICK CONFIGURATION 12 5 1 Access to the web server 12 5 2 Factory configuration 12 5 3 Loading the configuration 12 5 4 Option card detection 13 5 5 Removing an option card 13 6 SUPPORT 13 ...

Page 3: ...during installation use and maintenance of this device Symbol Description IEC60417 1641 Operating instructions IEC60417 5031 Direct current IEC60417 5032 Alternating current IEC60417 6042 Caution risk of electric shock IEC60417 6151 Caution infrared radiation IEC60417 6172 Disconnection all power plugs IEC60417 0434b Caution ...

Page 4: ... sure to follow the indications given by the pictograms in this manual The main pictograms are identified below indicates advice a recommendation or a technical explanation indicates that special attention needs to be paid indicates that misuse or failure to follow the instructions could result in a electrical danger This information must be taken into account when installing or using the product ...

Page 5: ... sources if both AC and DC power supply options are present turning off the switch on the rear panel will not disconnect all power supply sources Ensure that all power supply sources have been removed from the Netsilon device before taking off the cover and opening the product Only open the device in order to add or change option cards Never open the product with the power supply or supplies conne...

Page 6: ...er see Chapter 5 5 Removing an option card Once this uninstallation has been completed the product will redetect the option card with its new slot number OPEN NETSILON 1 Loosen and remove the 12 screws as shown below using a Torx T10 screwdriver 2 Remove the black cover INSTALL AN OPTION CARD 3 Determine the location of the option card respect slot compatibility 4 Remove the aluminium cover from t...

Page 7: ...ace the washer and screw the nut back onto the BNC connector s to tighten it onto the aluminium cover 8 Perform the following operations Ethernet RJ45 Ethernet SFP PTP option card connect the SATA cable linking the Network card s or PTP to the Netsilon motherboard Slot A Slot B Slot C Slot D SATA slot A SATA slot B SATA slot C SATA slot D This operation is valid for the Network option card RJ45 th...

Page 8: ... position the jumper to select the input impedance 4 7K 600 50 Ohms or high impedance no jumper By default the jumper is positioned on the option card for 600 Ohms Jumper This operation is only valid for the IRIG INPUT option card 9 Close up the Netsilon device by refitting the black cover identically to its original condition 10 Connect the power supply and turn the switch to ON I 11 Connect the ...

Page 9: ...must be installed in slots A and B Connectors 2 SFP Module types Description SX Colour black 1000 BaseSX LC Duplex Fiber connector Wavelength 850 nm LX Colour blue 1000 BaseLX LC Duplex Fiber connector Wavelength 1310 nm We recommend using BODET modules SX and LX Other SFP MSA compatible Multi Source Agreement modules can be used but there is no guarantee that they will work module RJ45 not compat...

Page 10: ...T SFP Customisable frequency output on SMA connector IRIG INPUT Option card ref 907 947 The IRIG INPUT option card can be installed in any slot Pluggable screw terminal BNC connector Jumper GND R B R A GND Two colour LED One option card maximum per Netsilon Connections IRIG AM and DCLS BNC connector core shield DCLS RS422 pluggable screw terminal 3 81 mm Status of the two colour LED bottom right o...

Page 11: ...s per Netsilon Connections IRIG AM and DCLS BNC connectors core shield DCLS RS422 pluggable screw terminal 3 81 mm Each output is programmable as either AM output on BNC DCLS output on BNC DCLS RS422 output on pluggable screw terminal Status of the two colour LED bottom right of the option card Red flashing card disciplining no transmission Green flashing transmission in progress at least on one o...

Page 12: ...ns html 5 2 Factory configuration To perform a factory configuration reset via the Netsilon web server follow these steps 1 SYSTEM menu Tools Updating and backup 2 Click and the following window will appear All configurations will be lost in the event of a factory configuration reset The link to the web server will be broken because the IP address is lost it is necessary to reconfigure the network...

Page 13: ...low these steps 1 SYSTEM menu Tools Option cards 2 Select the option card to be removed 3 Click and the following window will appear If this removal is performed but the option card is still present or moved to another slot it will be detected again when the user returns to this menu The product may restart 6 SUPPORT To request technical support for this equipment fill in the contact form at http ...

Reviews: