421
7.2.3
AC Characteristics
Clock Timing
Table 7.14
Clock Timing
Condition A*: V
CC
= 2.7 V to 3.6 V, AV
CC
= 2.7 V to 3.6 V, V
ref
= 2.7 V to AV
CC
,
V
SS
= AV
SS
= 0 V, ø = 2 MHz to 20 MHz, T
a
= –20°C to +75°C (regular
specifications), T
a
= –40°C to +85°C (wide-range specifications)
Condition B:
V
CC
= 3.0 V to 3.6 V, AV
CC
= 3.0 V to 3.6 V, V
ref
= 3.0 V to AV
CC
,
V
SS
= AV
SS
= 0 V, ø = 2 MHz to 33 MHz, T
a
= –20°C to +75°C (regular
specifications), T
a
= –40°C to +85°C (wide-range specifications)
Note: * In planning stage
Condition A
Condition B
Test
Item
Symbol
Min
Max
Min
Max
Unit
Conditions
Clock cycle time
t
cyc
50
500
30.3
500
ns
Figure7.2
Clock pulse high width
t
CH
20
—
10
—
ns
Figure7.2
Clock pulse low width
t
CL
20
—
10
—
ns
Clock rise time
t
Cr
—
5
—
5
ns
Clock fall time
t
Cf
—
5
—
5
ns
Reset oscillation settling
time (crystal)
t
OSC1
10
—
10
—
ms
Figure7.3
Software standby oscillation
settling time (crystal)
t
OSC2
10
—
10
—
ms
External clock output delay
settling time
t
DEXT
500
—
500
—
µ
s
Figure7.3