193
SIGNAMAX LLC • www.signamax.eu
Ethernet OAM link monitoring. The value range is
1-65535.
【
Default Status
】
threshold low
threshold-value
: 1:threshold high
threshold-value
:
none.
ethernet oam link-monitor frame action
This command is used to set the error response processing of error
frame checking of Ethernet OAM link monitoring. Checking error frames
is to check whether there are error frames within each period. If there
are error frames and the threshold is exceeded, report error.
The no format of the command is used to recover the default value.
ethernet oam link-monitor frame action threshold {low | high} {none
| error-disable-interface}
no ethernet oam link-monitor frame action threshold {low | high}
[none | error-disable-interface]
Syntax
Description
low
To set the error response processing of the low
threshold of error frame checking of Ethernet
OAM link monitoring
high
To set the error response processing of the high
threshold of error frame checking of Ethernet
OAM link monitoring
none
To set the error response processing of error
frame checking of Ethernet OAM link monitoring
as not process
error-disable-interface
To set the error response processing of error
frame checking of Ethernet OAM link monitoring
as shutdown the interface
【
Default Status
】
By default, do not process the error response.
ethernet oam link-monitor frame-period window
This command is used to set the window period of error frame checking
of Ethernet OAM link monitoring. Error frame period is to set a certain
number of frames as a checking period. Checking error frames
periodically is to check whether there are error frames within each period.
If there are error frames and the threshold is exceeded, report error.
The no format of the command is used to recover the default value.
ethernet oam link-monitor frame-period window
window-value
no ethernet oam link-monitor frame-period window [
window-value
]
Syntax
Description
window-value
To set the window period of error frame checking
of Ethernet OAM link monitoring. The value
range is 1-60 and the unit is second.
【
Default Status
】
window-value
: 1s
Содержание 065-7434
Страница 1: ...24 Port 10 100 L3 Switch Model 065 7434 Configuration Guide Revision A1 ...
Страница 245: ...245 SIGNAMAX LLC www signamax eu Application Example Example of configuring DHCP Snooping ...
Страница 302: ...302 SIGNAMAX LLC www signamax eu Default status no switching interface ...
Страница 368: ......
Страница 655: ...287 SIGNAMAX LLC www signamax eu Sub VLAN members in the system ...