156
SIGNAMAX LLC • www.signamax.eu
UDLD Application Example
Application Example 1
UDLD Configuration Example
Port 0/0 of local Switch A connects to Port 0/1 of local Switch B via fiber.
Configure UDLD function on the link to detect the connection status of
the link.
The configuration of Switch A:
Command
Description
SwitchA(config)# port 0/0
To enter into port configuration mode
SwitchA
(config-port-0/0)
#udld
port
aggressive
To configure aggressive working mode of
UDLD on port port0/0
SwitchA (config-port-0/0) #exit
To exit the port configuration mode
SwitchA (config)#udld message time 16
To configure time space of packet sending
as 16s
SwitchA(config)#udld enable
To enable Global UDLD
SwitchA (config)#exit
To finish UDLD configuration
The configuration of Switch B:
Command
Description
SwitchA(config)# port 0/1
To enter into port configuration mode
SwitchA (config-port-0/1) #udld port
aggressive
To configure aggressive working mode of
UDLD on port port0/1
SwitchA (config-port-0/1) #exit
To exit the port configuration mode
SwitchA(config)#udld enable
To enable Global UDLD
SwitchA (config)#exit
To finish UDLD configuration
Notes
In order to ensure the normal working of UDLD protocol, the switches
are configured with the same UDLD working mode.
Содержание 065-7434
Страница 1: ...24 Port 10 100 L3 Switch Model 065 7434 Configuration Guide Revision A1 ...
Страница 245: ...245 SIGNAMAX LLC www signamax eu Application Example Example of configuring DHCP Snooping ...
Страница 302: ...302 SIGNAMAX LLC www signamax eu Default status no switching interface ...
Страница 368: ......
Страница 655: ...287 SIGNAMAX LLC www signamax eu Sub VLAN members in the system ...