96
SIGNAMAX LLC • www.signamax.eu
description
LINE
description of the output alarm.
<0-2>
means selecting three alarm port
numbers.
By default, LINE is “
-
”.
alarm
{in|out} <0-2>
logic
{on|off}
In
means the logic selection of input
alarm; out means the logic selection of
the output alarm.
On
means that the external device alarm
signal logic are different from the logic of
the system input or output alarm, when
the logic of the system input or output
alarm logic is different from the external
device alarm signal logic, you can adjust
it until they are consistent.
The default value is
on
.
config
View Status Information
The related commands are as follows:
Command
Description
Configuration Mode
show alarm
{in|out}
In
means to display the status
information of all input alarms;
out
means to display the status information
of all output alarms.