Switch-A(config-port-0/0)# ethernet cfm mep domain
dom_l7_vlan100 service-instance ser_vlan100 mpid
100
The MEP whose the domain level is
configured as 7 and ID as 100
Switch-A(config-port-0/0)# ethernet cfm enable
To enable the CFM function on the
port
Switch-A(config)# port 0/1
To specify port 0/1 and enter the
port mode
Switch-A(config-port-0/1)#port access vlan 100
VLAN 100 of the specified port
Switch-A(config-port-0/1)#
ethernet
cfm
mep
domaindom_l4_vlan100 service-instance ser_vlan100
mpid 400
The MEP whose the domain level is
configured as 4 and ID as 400
Switch-A(config-port-0/1)# ethernet cfm enable
To enable the CFM function on the
port
Switch-A(config-port-0/1)#exit
To exit the port mode
Switch-B configuration:
Command
Description
Switch-B(config)# vlan 100
To configure VLAN100 and enter
VLAN mode
Switch-B(config)#exit
To exit VLAN mode
Switch-B(config)#
ethernet
cfm
domain
dom_l4_vlan100 level 4 outward
To create the maintenance domain
dom_l4_vlan100,
specify
the
domain level as 4, specify the
domain direction as outward and
enter the ether-cfm mode
Switch-B(config-ethernet-cfm)#
service-instance
ser_vlan100 vlan 100
To create the service instance, bind
it with VLAN 100 and enter
ethernet-si mode
Switch-B(config-ethernet-si)#exit
To exit ethernet-si mode
Switch-B(config-ethernet-cfm)#exit
To exit ethernet-cfm mode
Switch-B(config)#
ethernet
cfm
domain
dom_l7_vlan100 level 7
To create the maintenance domain
dom_l7_vlan100,
specify
the
domain level as 7 and enter the
ether-cfm mode
Switch-B(config-ethernet-cfm)#
service-instance
ser_vlan100 vlan 100
To create the service instance, bind
it with VLAN 100 and enter
ethernet-si mode
Switch-B(config-ethernet-si)#exit
To exit ethernet-si mode
Switch-B(config-ethernet-cfm)#exit
To exit ethernet-cfm mode
Switch-B(config)# port 0/0
To specify port 0/0 and enter the
port mode
Switch-B(config-port-0/0)#port access vlan 100
VLAN 100 of the specified port
Switch-B(config-port-0/0)# ethernet cfm mep domain
dom_l7_vlan100 service-instance ser_vlan100 mpid
200
The MEP whose the domain level is
configured as 7 and ID as 200
Switch-B(config-port-0/0)# ethernet cfm enable
To enable the CFM function on the
port
Switch-B(config)# port 0/1
To specify port 0/1 and enter the
Содержание 065-7434
Страница 1: ...24 Port 10 100 L3 Switch Model 065 7434 Configuration Guide Revision A1 ...
Страница 245: ...245 SIGNAMAX LLC www signamax eu Application Example Example of configuring DHCP Snooping ...
Страница 302: ...302 SIGNAMAX LLC www signamax eu Default status no switching interface ...
Страница 368: ......
Страница 655: ...287 SIGNAMAX LLC www signamax eu Sub VLAN members in the system ...