251
SIGNAMAX LLC • www.signamax.eu
automatically; it manually configures electricity to PD
equipment and it does not manage power.
dynamic-fifs
Dynamic-FIFS (First In First Service) mode: it automatically
detects the PD equipment and it is automatically electric
charging; it has dynamic FIFS power management mode.
When the actual power which is needed by the new
connected PD is less than rest useable power, the mode
does not supply power to it.
dynamic-priority
Dynamic-PRI mode; it automatically detects the PD
equipment and it is automatically electric charging; it has
dynamic priority power management mode. When the actual
power which is needed by the new connected PD is less
than rest useable power, the port which is supplying electric
is checked from port with the lowest priority. If the priority
of port is smaller than the priority of new inserting PD port,
the electricity of the port will be cut off. Check and cut off
the electricity orderly until that the rest useable power
satisfies the requirement of new inserting PD, then supply
electricity to the new inserting PD. If after checking, the rest
useable power can not satisfy the requirement of the port,
the mode supplies no electricity to the new PD.
static-fifs
Static- FIFS (First In First Service): it automatically detects
the PD equipment and it is automatically electric charging; it
has dynamic FIFS power management mode. When the
hierarchical power of the new connected PD is less than rest
useable power, the mode supplies no electricity to it.
static-priority
Dynamic-PRI mode; it automatically detects the PD
equipment and it is automatically electric charging; it has
dynamic priority power management mode. When the actual
power which is needed by the new connected PD is less
than rest useable power, the port which is supplying electric
is checked from port with the lowest priority. If the priority
of port is smaller than the priority of new inserting PD port,
the electricity of the port will be cut off. Check and cut off
the electricity orderly until that the rest useable power
satisfies the requirement of new inserting PD, then supply
electricity to the new inserting PD. If after checking, the rest
useable power can not satisfy the requirement of the port,
the mode supplies no electricity to the new PD.
【
Default Status
】
Use static-FIFS management mode.
Notes
The total power of POE system which is supplied by the 065-7434
Signamax 24-Port 10/100 L3 Switch serial switches can support the
largest power of POE port to supply electricity at the same time. In this
way, the four management modes including static and dynamic are not
needed and the manually management mode can supply more
management, therefore default the manually management mode.
power guard-band
Содержание 065-7434
Страница 1: ...24 Port 10 100 L3 Switch Model 065 7434 Configuration Guide Revision A1 ...
Страница 245: ...245 SIGNAMAX LLC www signamax eu Application Example Example of configuring DHCP Snooping ...
Страница 302: ...302 SIGNAMAX LLC www signamax eu Default status no switching interface ...
Страница 368: ......
Страница 655: ...287 SIGNAMAX LLC www signamax eu Sub VLAN members in the system ...