242
SIGNAMAX LLC • www.signamax.eu
Syntax
Description
rpdelaylarm
The bi-directional delay alarm threshold; the value range is
from 1 to 5000; the unit is milli-second.
【
Default Status
】
The default value of the parameter is 500ms.
avgjitter-alarm
jitterlarm
This command is used to set Jitter alarm threshold of the sla service.
When the statistics result of Jitter exceeds the threshold, execute the
alarming operation. The Jitter is defined as the difference between two
consecutive bi-directional delays. It is used to describe the stability of the
connection. The unit is ms.
Syntax
Description
jitterlarm
The Jitter alarm threshold; the value range is from 1 to 5000;
the unit is ms.
【
Default Status
】
The default value of the parameter is 500ms.
avglost-alarm
lostlarm
This command is used to set the alarm threshold of the packet loss rate
of the sla service. When packet loss rate exceeds the alarm threshold,
execute the alarming operation. The unit is percent.
Syntax
Description
lostlarm
The
alarm threshold of the packet loss rate; the value range
is from 1
to 100; the unit is percent.
【
Default Status
】
The default value of the parameter is 500%.
Содержание 065-7434
Страница 1: ...24 Port 10 100 L3 Switch Model 065 7434 Configuration Guide Revision A1 ...
Страница 245: ...245 SIGNAMAX LLC www signamax eu Application Example Example of configuring DHCP Snooping ...
Страница 302: ...302 SIGNAMAX LLC www signamax eu Default status no switching interface ...
Страница 368: ......
Страница 655: ...287 SIGNAMAX LLC www signamax eu Sub VLAN members in the system ...