321
SIGNAMAX LLC • www.signamax.eu
ip tcp round-trip
{
round-trip
}
no ip tcp round-trip
default ip tcp round-trip
Syntax
Description
round-trip
TCP max round-trip time, and the value range is
1-100s.
【
Default status
】
The default value is 3s.
The no command and default command are used to recover the default value of TCP max
round-trip time.
Configure Idle Time
ip tcp idle-timeout
ip tcp idle-timeout
{
idle-time
}
no ip tcp idle-timeout
default ip tcp idle-timeout
Syntax
Description
idle-time
TCP idle time, and the value range is 3-144000s.
【
Default status
】
The default value is 14400s (2 hours).
The no command and default command are used to recover the default value of the idle time.
Configure Timer Value
ip tcp init-timeout
ip tcp init-timeout
{
init-time
}
no ip tcp init-timeout
default ip tcp init-timeout
Syntax
Description
init-timeout
TCP setting connection timer, and the value range is 2-30000.
【
Default status
】
The default value is 150 and the unit is 0.5s.
The no command and default command are used to recover the default value of the timer.
Configure max keepalive testing times
ip tcp keep-count
ip tcp keep-count
{
keep-count
}
no ip tcp keep-count
default ip tcp keep-count
Syntax
Description
keep-count
TCP keepalive times, and the value range is
3-20.
【
Default status
】
The default value is 8.
The no command and default command are used to recover the default value of TCP keepalive
times.
Содержание 065-7434
Страница 1: ...24 Port 10 100 L3 Switch Model 065 7434 Configuration Guide Revision A1 ...
Страница 245: ...245 SIGNAMAX LLC www signamax eu Application Example Example of configuring DHCP Snooping ...
Страница 302: ...302 SIGNAMAX LLC www signamax eu Default status no switching interface ...
Страница 368: ......
Страница 655: ...287 SIGNAMAX LLC www signamax eu Sub VLAN members in the system ...