![SignaMax 065-7434 Скачать руководство пользователя страница 564](http://html.mh-extra.com/html/signamax/065-7434/065-7434_configuration-manual_1268429564.webp)
196
SIGNAMAX LLC • www.signamax.eu
checking of Ethernet OAM link monitoring
none
To set the threshold of error frame second
checking of Ethernet OAM link monitoring as not
monitor
threshold-value
To set the threshold of error frame second
checking of Ethernet OAM link monitoring. The
value range is 1-65535.
【
Default Status
】
threshold low
threshold-value
:
1
;
threshold high
threshold-value
:
none
ethernet oam link-monitor symbol action
This command is used to set the error response processing of error
frame second checking of Ethernet OAM link monitoring. Error frame
second is that if there are error frames within a second, the second is
called error frame second. Checking error frame second is to check
whether there are error frame seconds within a period. If there are error
frame seconds and the threshold is exceeded, report error.
The no format of the command is used to recover the default value.
ethernet oam link-monitor frame-seconds action threshold {low |
high} {none | error-disable-interface}
no ethernet oam link-monitor frame-seconds action threshold {low |
high} [none | error-disable-interface]
Syntax
Description
low
To set the error response processing of the low
threshold of error frame second checking of
Ethernet OAM link monitoring
high
To set the error response processing of the high
threshold of error frame second checking of
Ethernet OAM link monitoring
none
To set the error response processing of error
frame second checking of Ethernet OAM link
monitoring as not process
error-disable-interface
To set the error response processing of error
frame second checking of Ethernet OAM link
monitoring as shutdown the interface
【
Default Status
】
By default, the error response is not processed.
ethernet oam log-message shutdown
This command is used to disable the log information of Ethernet OAM.
The no format of the command is used to recover the default value.
ethernet oam log-message shutdown
no ethernet oam log-message shutdown
【
Default Status
】
By default, the log information of Ethernet OAM is
Содержание 065-7434
Страница 1: ...24 Port 10 100 L3 Switch Model 065 7434 Configuration Guide Revision A1 ...
Страница 245: ...245 SIGNAMAX LLC www signamax eu Application Example Example of configuring DHCP Snooping ...
Страница 302: ...302 SIGNAMAX LLC www signamax eu Default status no switching interface ...
Страница 368: ......
Страница 655: ...287 SIGNAMAX LLC www signamax eu Sub VLAN members in the system ...