ID Dx.
Message
Description
Temperature in device too low
Remedy
–
Check ambient conditions
Default: Stop category 1 (256)
Classifica-
tion
Can be parameterised: No
Default: save (1)
03 | 01 | 00045
(50397229)
Temperature in device
too low
Error
memory
Can be parameterised: No
Warning threshold: Device overtemperature
Remedy
–
Temperature display plausible?
–
Device fan faulty?
–
Device overloaded?
–
Check installation conditions; control cab-
inet fan filter dirty?
–
Check drive layout (possible overloading
during continuous operation)
Default: Warning (16)
Classifica-
tion
Can be parameterised: No
Default: save (1)
03 | 01 | 00046
(50397230)
Warning threshold:
Device overtemperat-
ure
Error
memory
Can be parameterised: No
Device overtemperature
Remedy
–
Temperature display plausible?
–
Device fan faulty?
–
Device overloaded?
–
Check installation conditions; control cab-
inet fan filter dirty?
–
Check drive layout (possible overloading
during continuous operation)
Default: Stop category 1 (256)
Classifica-
tion
Can be parameterised: No
Default: save (1)
03 | 01 | 00047
(50397231)
Device overtemperat-
ure
Error
memory
Can be parameterised: No
Warning threshold: Temperature in power unit too low
Remedy
–
Check ambient conditions
03 | 02 | 00048
(50462768)
Warning threshold:
Temperature in power
unit too low
Classifica- Default: Warning (16)
Diagnostics and fault clearance
448
Festo — CMMT-ST-SW — 2019-02
Summary of Contents for CMMT-ST-SW
Page 615: ......