ID Dx.
Message
Description
11 | 03 | 00176
(184746160)
CRC error in user file
memory
Can be parameterised: No
The user file is invalid
Remedy
–
Restart device
Default: Info (4)
Classifica-
tion
Can be parameterised: No
Default: save (1)
11 | 03 | 00177
(184746161)
File: user file invalid
Error
memory
Can be parameterised: No
A new user file has been generated
Remedy
–
Information copies
Default: Info (4)
Classifica-
tion
Can be parameterised: No
Default: save (1)
11 | 03 | 00178
(184746162)
New user file has
been created
Error
memory
Can be parameterised: No
It was not possible to write to the user file
Remedy
–
Restart device
–
Service required
Default: Info (4)
Classifica-
tion
Can be parameterised: No
Default: save (1)
11 | 03 | 00179
(184746163)
Writing to user file not
possible
Error
memory
Can be parameterised: No
An unknown error was triggered for the user file
Remedy
–
Restart device
–
Service required
Default: Info (4)
Classifica-
tion
Can be parameterised: No
Default: save (1)
11 | 03 | 00180
(184746164)
Unknown user file
error
Error
memory
Can be parameterised: No
Writing of firmware failed
Remedy
–
Repeat transmission of firmware package
Default: Warning (16)
11 | 04 | 00181
(184811701)
Writing of firmware
failed
Classifica-
tion
Can be parameterised: No
Diagnostics and fault clearance
485
Festo — CMMT-ST-SW — 2019-02
Summary of Contents for CMMT-ST-SW
Page 615: ......