ID Px.
Parameters
Description
Displays whether the commutation angle saved in the parameter
set shall be valid.
This means:
–
0: invalid
–
1: valid
Access
read/−
Update
reinitialization
3229
Valid commutation
angle from user con-
figuration
Unit
−
Displays whether the current commutation status shall be valid.
This means:
–
0: invalid
–
1: valid
Access
read/−
Update
effective immediately
3230
Current commutation
angle valid
Unit
−
Specifies the current angular frequency as a filtered value.
Access
read/−
Update
effective immediately
3234
Electrical angular fre-
quency filtered
Unit
Hz
Determines whether the switch-on phase shall be checked as to
whether the detected motor encoder corresponds with the last
motor encoder used. The following applies: 0: motor change
check active, 1: motor change check inactive. The last motor
encoder used is stored after valid homing and saving in the
parameter set. The check compares the data in the memory of
the encoder with data stored in the parameter set of the device.
Access
read/write
Update
reinitialization
3236
Deactivation motor
change check
Unit
−
3237
Encoder permanently
homed
For single-turn encoders, determines whether the encoder shall
indicate the "Homed" status after activation. For encoders that
deliver the "Homed" status, a new homing run is not mandat-
ory.
This means:
–
0: inactive
–
1: active
Product configuration