ID Dx.
Message
Description
tion
Can be parameterised: Px.1852, value list:
Stop category 0 (4096)
Stop category 1 (256)
Stop category 2 (64)
Default: save (1)
06 | 00 | 00070
(100663366)
Invalid record table
parameter
Error
memory
Can be parameterised: Px.1853
The operating mode of the closed-loop controller (posi-
tion, speed, force, stop) does not match the parameterisa-
tion
Remedy
–
Check parameterisation of the closed-
loop controller
Default: Stop category 1 (256)
Classifica-
tion
Can be parameterised: No
Default: save (1)
06 | 00 | 00081
(100663377)
Closed-loop controller
operating mode inval-
id
Error
memory
Can be parameterised: No
The parameterisation of the notch filter frequency is inval-
id
Remedy
–
Check parameterisation of notch filter fre-
quency; notch filter frequency is greater
than half the scanning frequency
Default: Stop category 1 (256)
Classifica-
tion
Can be parameterised: No
Default: save (1)
06 | 00 | 00082
(100663378)
Notch filter frequency
invalid
Error
memory
Can be parameterised: No
Record table incorrect
Remedy
–
Check positioning record number
Default: Stop category 1 (256)
Classifica-
tion
Can be parameterised: Px.1850, value list:
Stop category 0 (4096)
Stop category 1 (256)
Stop category 2 (64)
Default: save (1)
06 | 00 | 00083
(100663379)
Record table incorrect
Error
memory
Can be parameterised: Px.1851
Diagnostics and fault clearance
457
Festo — CMMT-ST-SW — 2019-02