ID Px.
Parameters
Description
Specifies the amplification gain in the parameter sets for the PI-
element in the velocity controller.
Access
read/write
Update
effective immediately
2210
Velocity controller
amplification gain
Unit
−
Specifies the integration constant in the parameter sets for the
PI-element in the velocity controller.
Access
read/write
Update
effective immediately
2211
Velocity controller
integration constant
Unit
−
Specifies the amplification gain "Active current" in the paramet-
er sets for the PI-element in the current regulator.
Access
read/write
Update
effective immediately
2223
Amplification gain
current regulator (act-
ive current)
Unit
−
Specifies the integration constant "Active current" in the para-
meter sets for the PI-element in the current regulator.
Access
read/write
Update
effective immediately
2224
Integration constant
current regulator (act-
ive current)
Unit
−
Specifies the amplification gain "Reactive current" in the para-
meter sets for the PI-element in the current regulator.
Access
read/write
Update
effective immediately
2225
Amplification gain
current regulator
(reactive current)
Unit
−
Specifies the total inertia torque of the drive train (axis, gear
unit, motor, load). A value input by the user is overwritten with
the total of all inertias from the configured drive train, including
the load, by calculation of the control parameters.
Access
read/write
Update
effective immediately
2227
Total inertia
Unit
kgm²
Control
357
Festo — CMMT-ST-SW — 2019-02