Name
Parameters
ID Px.
+M
Resulting upper limit value torque (closed loop controller)
6105
–LIM1
Minimum torque
2218
+LIM1
Maximum torque
2219
Tab. 369 Legend for the block diagram of the current limiter
The resulting critical limits iq and are the result of the control limitation
è
The minimum and maximum torque affects the output of the velocity controller
è
Parameters and diagnostic messages
ID Px.
Parameters
Description
Specifies the reactive current setpoint for the current regulator.
Access
read/−
Update
effective immediately
87
Reactive current set-
point value
Unit
Arms
Specifies the limit value of the total current for the servo drive
controller.
Access
read/write
Update
effective immediately
856
Limit value total cur-
rent (closed loop con-
troller)
Unit
Arms
Specifies the minimum torque for torque limitation.
Access
read/−
Update
effective immediately
2218
Minimum torque
Unit
Nm
Specifies the maximum torque for torque limitation.
Access
read/−
Update
effective immediately
2219
Maximum torque
Unit
Nm
Specifies the resulting minimum torque for torque limitation.
Access
read/−
Update
effective immediately
6104
Resulting lower limit
value torque (closed
loop controller)
Unit
Nm
Control
370
Festo — CMMT-ST-SW — 2019-02