A maximum of 3 record sequences can be parameterised for every record of the record table. Every
record sequence defines a condition and a subsequent record. The condition (comparator) can com-
pare signals, states or parameters and is cyclically monitored. If one of the maximum of 3 conditions
returns the value "true", the associated subsequent record is started.
Parameters for the sequence of command records of the record table
ID Px.
Parameters
Description
Specifies the enabling condition that is to be monitored along
with the execution of the record.
Possible record enabling types
è
Record step enabling type parameter (ID Px.1831).
Access
read/write
Update
effective immediately
1831
Record step enabling
type
Unit
−
Specifies the number of the record from which the record
sequence starts (maximum 3 record sequence per record).
Access
read/write
Update
effective immediately
1832
Record sequencing
record number start
Unit
−
Specifies the number of the target record to which the record
sequence is targeted (maximum 1 target record per record
sequence).
Access
read/write
Update
effective immediately
1833
Record sequencing
record number target
Unit
−
Specifies the value of the time parameter
è
Record step enabling type parameter (ID Px.1831)
Access
read/write
Update
effective immediately
1834
Record sequencing
field time
Unit
s
Specifies the value of the first comparator type-dependent para-
meter
è
Record step enabling type parameter (ID Px.1831)
Access
read/write
Update
effective immediately
1835
Record sequencing
field 1
Unit
−
Motion control
289
Festo — CMMT-ST-SW — 2019-02