No.
Section/command
Description
The command can be executed if the following pre-
requisites are met:
–
The plug-in is connected to a device.
–
The plug-in has the master control.
–
The device is not in error status.
"Powerstage"
During activation of controller enable, a check determ-
ines whether a reinitialisation is required. If a reinitial-
isation is required, a query is displayed offering the fol-
lowing options:
–
"Ok": The reinitialisation is executed and controller
enable is activated.
–
"Cancel": The reinitialisation is not executed and
controller enable remains deactivated.
3
If another plug-in has the master control, an information
symbol is displayed over the deactivated command
"Powerstage".
The tool tip for the command "Powerstage" contains the
IP address and the port number of the device.
Function:
–
Send stop command to the servo drive (category 2
stop)
4
"Stop"
The command can be executed if the following pre-
requisite is met:
–
The plug-in is connected to a device.
–
The plug-in has the master control.
–
Controller enable is activated.
Function:
–
Acknowledge all cancelled diagnostic messages for
the servo drive
Additional information
è
5
"Acknowledge all"
The command can be executed if the following pre-
requisite is met:
–
The plug-in is connected to a device.
–
The plug-in has the master control.
6
Function:
–
Permanently save current parameterisation on the
device
CMMT-ST Plug-in
17
Festo — CMMT-ST-SW — 2019-02
Summary of Contents for CMMT-ST-SW
Page 615: ......