ID Px.
Parameters
Description
8611
Start value position
controller amplifica-
tion gain
Unit
−
Specifies the start value of auto tuning for the amplification gain
of the velocity controller.
Access
read/write
Update
effective immediately
8612
Start value velocity
controller amplifica-
tion gain
Unit
−
Specifies the start value of auto tuning for the integration con-
stant of the velocity controller.
Access
read/write
Update
effective immediately
8613
Start value velocity
controller integration
constant
Unit
−
Specifies the filter time constant of the velocity controller for the
layout of the controller parameters.
Access
read/write
Update
effective immediately
8614
Filter time constant
velocity controller
Unit
s
Specifies the filter time constant of the noise signal generator.
Access
read/write
Update
effective immediately
8615
Filter time constant
noise signal generator
Unit
s
Specifies the amplification gain of the noise signal generator.
Access
read/write
Update
effective immediately
8616
Amplification gain
noise signal generator
Unit
user defined
Specifies the signal selection of the noise signal generator. 1
uniform noise and 2 normally distributed noise
Access
read/write
Update
effective immediately
8617
Signal selection noise
signal generator
Unit
−
Control