ID Px.
Parameters
Description
Specifies the static limit value "Maximum current" created from
the minimum of the maximum values of the motor or servo drive
controller.
Access
read/−
Update
effective immediately
624
Resulting maximum
current
Unit
Arms
Specifies the static limit value "Minimum current" created from
the minimum of the maximum values of the motor or servo drive
controller with negative signs.
Access
read/−
Update
effective immediately
625
Resulting minimum
current
Unit
Arms
Specifies the dynamic limit value "Lower limit value of velocity"
specified by the user.
Access
read/write
Update
effective immediately
850
Lower limit value
velocity (closed loop
controller)
Unit
user defined
Specifies the dynamic limit value "Upper limit value of velocity"
specified by the user.
Access
read/write
Update
effective immediately
851
Upper limit value
velocity (closed loop
controller)
Unit
user defined
Specifies the dynamic limit value "Lower limit value of the
torque" specified by the user.
Access
read/write
Update
effective immediately
852
Lower limit value
torque (closed loop
controller)
Unit
Nm
Specifies the dynamic limit value "Upper limit value of the
torque" specified by the user.
Access
read/write
Update
effective immediately
853
Upper limit value
torque (closed loop
controller)
Unit
Nm
Control
365
Festo — CMMT-ST-SW — 2019-02