Parameters
Index.Subindex
Name
Data type
1212
0x2155.0D
Electrical angle
UINT32
1213
0x2155.0E
Electrical angular frequency
FLOAT32
Tab. 136 Objects
3.3.3.10
Parameters of the direction of rotation manager
The following parameters influence the direction of rotation of the drive:
ID Px.
Parameters
Description
Determines whether the reversal of the direction of rotation
shall be activated.
This means:
–
0: inactive
–
1: active
Access
read/write
Update
reinitialization
1170
Reversing the direc-
tion of rotation
Unit
−
Determines whether the encoder signal shall be inverted.
This means:
–
0: inactive (do not invert the encoder signal)
–
1: active (invert the encoder signal)
One encoder is allocated to every index
è
Index for the Invert encoder signal parameter (Px.1171).
Access
read/write
Update
reinitialization
1171
Invert encoder signal
Unit
−
Specifies whether the sequence of phases is swapped. The usu-
al phase sequence for the servomotor to turn clockwise is
ascending (U, V, W). If the servomotor has the phase sequence
U, W, V, the phase sequence is reversed. 0 for the phase
sequence U, V, W and 1 for the phase sequence U, W, V. For a
stepper motor, the phase sequence for 0 is the assignment A-#A
and B-#B. For the phase sequence equal to 1, the assignment A-
#A and #B-B is. Changing the phase sequence changes the
rotating field of the motor.
Access
read/write
1172
Phase rotation
Update
reinitialization
Product configuration