ID Dx.
Message
Description
Cycle time is not an integral multiple of 1 ms
Remedy
–
Check whether the cycle time is an integ-
ral multiple of 1 ms
Default: Stop category 1 (256)
Classifica-
tion
Can be parameterised: No
Default: save (1)
08 | 00 | 00243
(134217971)
Invalid cycle time
Error
memory
Can be parameterised: No
The process data is invalid
Remedy
–
Check process data mapping
Default: Stop category 1 (256)
Classifica-
tion
Can be parameterised: No
Default: save (1)
08 | 03 | 00141
(134414477)
The process data is
invalid
Error
memory
Can be parameterised: No
Configuration of process data invalid
Remedy
–
Check parameterisation of EtherCAT com-
munication
Default: Stop category 1 (256)
Classifica-
tion
Can be parameterised: No
Default: save (1)
08 | 04 | 00142
(134480014)
EtherCAT process
data invalid
Error
memory
Can be parameterised: No
EtherCAT process data communication failed
Remedy
–
Check EtherCAT communication (plug,
master), etc.
Default: Stop category 1 (256)
Classifica-
tion
Can be parameterised: No
Default: save (1)
08 | 04 | 00143
(134480015)
EtherCAT process
data communication
failed
Error
memory
Can be parameterised: No
Process data not received at Sync time
Remedy
–
Check interaction between process data
and sync time in open-loop control
08 | 04 | 00281
(134480153)
Process data not
received at Sync time
Classifica- Default: Stop category 1 (256)
Diagnostics and fault clearance
475
Festo — CMMT-ST-SW — 2019-02