ID Px.
Parameters
Description
Specifies the limit value "Maximum output voltage" for the out-
puts of the PI-elements (reactive current/active current) in the
current regulator.
Access
read/−
Update
effective immediately
88
Maximum output
voltage
Unit
V
Specifies the actual value of the phase V current.
Access
read/−
Update
effective immediately
310
Actual phase V cur-
rent value
Unit
A
Specifies the actual reactive current at the output of the current
transformation.
Access
read/−
Update
effective immediately
813
Actual reactive cur-
rent value
Unit
Arms
Specifies the actual active current at the output of the current
transformation.
Access
read/−
Update
effective immediately
814
Actual active current
value
Unit
Arms
Activate equalisation of the control parameters of the current
regulator for active current and reactive current
–
0: inactive; for the calculation of the controller parameters,
the plug-in only calculates the active current regulator. The
reactive current regulator remains unaffected.
–
1: active; for the calculation of the controller parameters,
the plug-in synchronises the parameters for the active cur-
rent and the reactive current.
Access
read/write
Update
effective immediately
819
Control parameter
equalisation for active
and reactive current
regulators
Unit
−
Control
353
Festo — CMMT-ST-SW — 2019-02
Summary of Contents for CMMT-ST-SW