ID Px.
Parameters
Description
Specifies the current position of the singleturn scanning of the
encoder.
Access
read/−
Update
effective immediately
3603
Single-turn position
Unit
−
Specifies the current position of the multiturn scanning of the
encoder.
Access
read/−
Update
effective immediately
3604
Multi-turn numerator
Unit
−
Specifies the size of the BiSS-C checksum in bits.
Access
read/−
Update
effective immediately
3610
CRC BiSS-C
Unit
−
Defines the baud rate at which the encoder data is transmitted.
Access
read/write
Update
reinitialization
3612
Baud rate
Unit
−
Determines whether the correction table of the encoder is used.
This means:
–
0: inactive
–
1: active
Access
read/write
Update
effective immediately
3613
Activation of correc-
tion table
Unit
−
Defines whether the extended encoder data of the encoder
should be used.
This means:
–
0: inactive
–
1: active
Access
read/write
Update
reinitialization
3618
Activation read out
extended encoder
data
Unit
−
Product configuration