ID Dx.
Message
Description
Default: Stop category 1 (256)
Classifica-
tion
Can be parameterised: No
Default: save (1)
03 | 02 | 00051
(50462771)
Power unit overtem-
perature
Error
memory
Can be parameterised: No
Parameterisation of homing run invalid
Remedy
–
Travel to hardware limit switch (limit
switch configured)
Default: Stop category 1 (256)
Classifica-
tion
Can be parameterised: Px.8450, value list:
Stop category 0 (4096)
Stop category 1 (256)
Stop category 2 (64)
Default: save (1)
05 | 01 | 00056
(83951672)
Configuration of hom-
ing run invalid
Error
memory
Can be parameterised: Px.8451
Homing: Timeout
Remedy
–
Check configuration of homing run
(timeout, type)
–
At end stop: check parameters for stand-
still window and limiting current
Default: Stop category 1 (256)
Classifica-
tion
Can be parameterised: Px.8452, value list:
Stop category 0 (4096)
Stop category 1 (256)
Stop category 2 (64)
Default: save (1)
05 | 01 | 00057
(83951673)
Homing: Timeout
Error
memory
Can be parameterised: Px.8453
Homing: Search path exceeded
Remedy
–
Check arrangement of slide in relation to
limit switch/end stop
–
Configuration of search path
05 | 01 | 00058
(83951674)
Homing: Search path
exceeded
Classifica- Default: Stop category 1 (256)
Diagnostics and fault clearance
450
Festo — CMMT-ST-SW — 2019-02
Summary of Contents for CMMT-ST-SW