ID Px.
Parameters
Description
11615
Current position
Unit
−
Determines the encoder type set to which the encoder interface
shall be set after the next reinitialisation. The selection of the
encoder type can influence the amount of supply voltage
provided for the encoder. Incorrect parameterisation can dam-
age the connected encoder due to impermissibly high supply
voltage! In case of EnDat and Hiperface encoders, this is preven-
ted by protection mechanisms.
Possible encoder types
è
Tab. 124 Encoder selection values list (Px.11616).
Access
read/write
Update
reinitialization
11616
Encoder selection
Unit
−
Specifies the encoder type currently configured for the encoder
interface.
Access
read/−
Update
effective immediately
11617
Active encoder
Unit
−
Determines the filter time constant of the velocity filter. The fil-
ter time constant prevents or dampen signal noise in the
encoder signal.
Access
read/write
Update
effective immediately
11618
Velocity filter filter
time constant
Unit
s
Displays the actual value of the acceleration unfiltered
Access
read/−
Update
effective immediately
71500
Actual acceleration
value unfiltered
Unit
Inci/s²
Displays the actual value of the acceleration filtered
Access
read/−
Update
effective immediately
71501
Actual acceleration
value filtered
Unit
Inci/s²
Product configuration