ID Px.
Parameters
Description
Hysteresis for the modulo position for secure detection during a
modulo run
Access
read/write
Update
effective immediately
112736
Modulo hysteresis
Unit
user defined
Specifies the currently used hysteresis for the modulo position
for secure detection during a modulo run.
Access
read/−
Update
effective immediately
112737
Current modulo hys-
teresis
Unit
user defined
Tab. 392 Parameters
Cam controller parameter mode (Px.112700)
Value
Meaning
Description
0
Inactive
The cam controller function is inactive
1
ON (manual)
The trigger output is activated when the cam controller
function is activated. The trigger output can therefore
be activated manually for test purposes.
2
OFF (manual)
The trigger output is activated when the cam controller
function is deactivated. The trigger output can there-
fore be deactivated manually for test purposes.
3
Force last status
The status present at the current point in time remains
permanently.
4
Switch-on time (manual)
Activation for the duration of the parameterised
switching time (Px.112707).
5
Switch-off time (manual)
Deactivation for the duration of the parameterised
switching time (Px.112707).
6
Automatic
The switching status of the trigger output is controlled
automatically. The switching points depend on the
parameterisation of the individual cams.
7
Set modulo position
Sets the modulo position to the value saved in the
Px.112733 parameter.
Tab. 393 Possible modes of the cam controller function
Diagnostic messages
No specific diagnostic messages are allocated to the function.