ID Dx.
Message
Description
Drive has left the target range
Remedy
–
Check target range window and recovery
time
–
Application monitoring reasonable? Pos-
sibly deactivate monitoring
Default: Warning (16)
Classifica-
tion
Can be parameterised: Px.4669, value list:
Stop category 0 (4096)
Stop category 1 (256)
Stop category 2 (64)
Warning (16)
Info (4)
Ignore (2)
Default: save (1)
07 | 02 | 00129
(117571713)
Out of target range
Error
memory
Can be parameterised: Px.4670
Pushback monitoring reports error
Remedy
–
Check recovery time
–
Application monitoring reasonable? Pos-
sibly deactivate monitoring
Default: Info (4)
Classifica-
tion
Can be parameterised: Px.4671, value list:
Stop category 0 (4096)
Stop category 1 (256)
Stop category 2 (64)
Warning (16)
Info (4)
Ignore (2)
Default: do not save (0)
07 | 02 | 00130
(117571714)
Pushback monitoring
Error
memory
Can be parameterised: Px.4672
Residual distance too low
Remedy
–
none (info only)
07 | 02 | 00131
(117571715)
Residual distance too
low
Classifica- Default: Info (4)
07 | 02 | 00131
(117571715)
Residual distance too
low
tion
Can be parameterised: Px.4686, value list:
Stop category 0 (4096)
Stop category 1 (256)
Stop category 2 (64)
Warning (16)
Diagnostics and fault clearance